Our Line of Top Quality Vacuum Equipment

Straight Vac

Features

17m3 Complies with CSA B620, TC 407/412 – Current Edition

  • 17 m³ – 3740 Imp Gal +/- 3% outage
  • Full opening hydraulic rear door, Hoist cylinder and Vibrator
  • Full length subframe c/w 1/8″ checkered mild steel/fender assembly, rear skirt and bumper
  • Robuschi RB-DV-85 PD High efficiency tri-lobe design Blower
  • 6″ Plumbing, 6″ Cyclone with clean-out door & heated drain valve
  • 6″ Load valve lower center with 4″ sandpipe D/S and 4” P/S. All valves pneumatically operated.
  • Steel Vertical , deck cabinets & fitting boxes
  • D O T Lighting as required c/w L.E.D. work lights

Specs & Configurations

Standard Configuration

Custom Vac CV85 Vacuum System (Tri-Drive Mounted)

Design:

Tank Construction, tank design and associated equipment are compliant with Transport Canada TC407/412 CSA B620 current edition and ASME section VIII Division 1, as enforced by ABSA Boiler and Pressure Vessel Code.  

Debris Tank 17 m³ (3740 Imp Gal +3% Outage):

  • 78″ Diameter x 17’ seam to seam
  • Pressure vessel hydrotested to 40 PSI
  • Global hydraulic vibrator
  • 4 stage double acting hydraulic hoist cylinder
  • Full opening hydraulic lift rear door c/w locking style top hinge and 6 pin wheel door locks
  • Recessed liquid level indicator on the D/S c/w indicator with grab handle
  • 3″ x 30 PSI pressure relief vent
  • Locking style top hinge to safely hold the rear door open
  • Operating Temperature -20 degrees F to 200 degrees F
  • 8″ Primary internal shutoff SS float ball and rubber seat assembly with 6″ flanged outlet
  • 4” Betts load valve c/w 6″ sandpipe and aluminum camlock/cap D/S
  • 4″ Betts load valve c/w aluminum camlock/cap P/S
  • 6” Betts discharge valve c/w aluminum cap (Center) All rear valves heated, air and equipped with flip style valve controls
  • Robuschi RB-DV 85 High Efficiency Tri-Lobe Design
  • 27” Hg Maximum Vacuum (1600 CFM)
  • Oil Free Operation (Except Sealed Reservoirs)
  • 6″ Four-Way Divertor Valve (Vacuum to Pressure Modes)
  • 6″ Double Door Check Valve (To Prevent Blower Back Spin)
  • Pre-stage housing c/w 16″ Dia. x 5 Micron Rating (Washable) Blower Filter
  • High Torque/High Temp Blower Drive Coupling with Flexible Insert
  • One Exhaust Silencer, One Intake Silence
  • High temperature blower alarm c/w gauge
  • Diesel flush ball valve assembly

Rig to Pull Pup (Standard)

  • Doghouse
  • Hydraulics required c/w hose and fittings to operate trailer functions

Toolbox

  • One 60” W x 17” D x 17” H steel box c/w 2 access doors D/S (slope back)
  • Two 22” W x 22” D x 40” H vertical cabinets c/w heater, lights, hooks D/S and P/S
  • 2 rear skirt fitting boxes

Paint / Coating

  • Entire tank and body of vacuum system will be sandblasted, primed and painted up to 2 colors

Frame, Decking, Trim

  • Full length 1/8” checker plate hose tray/fender assembly with heavy duty outrigger supports & 1-1/4” steel tubing handrails, close in plates
  • Ladder P/S
  • Code rear bumper (flip up style)
  • Slide out style chain hangers
  • 4 flip style placards
  • Mud flaps c/w anti-sail brackets
  • 20 lb. fire extinguisher with mounting bracket and cover
  • 50’ ground cable c/w reel