Our Line of Top Quality Vacuum Equipment
Straight Vac

Features
17m3 Complies with CSA B620, TC 407/412 – Current Edition
- 17 m³ – 3740 Imp Gal +/- 3% outage
- Full opening hydraulic rear door, Hoist cylinder and Vibrator
- Full length subframe c/w 1/8″ checkered mild steel/fender assembly, rear skirt and bumper
- Robuschi RB-DV-85 PD High efficiency tri-lobe design Blower
- 6″ Plumbing, 6″ Cyclone with clean-out door & heated drain valve
- 6″ Load valve lower center with 4″ sandpipe D/S and 4” P/S. All valves pneumatically operated.
- Steel Vertical , deck cabinets & fitting boxes
- D O T Lighting as required c/w L.E.D. work lights
Specs & Configurations
Standard Configuration
Custom Vac CV85 Vacuum System (Tri-Drive Mounted)
Design:
Tank Construction, tank design and associated equipment are compliant with Transport Canada TC407/412 CSA B620 current edition and ASME section VIII Division 1, as enforced by ABSA Boiler and Pressure Vessel Code.
Debris Compartment
Debris Tank 17 m³ (3740 Imp Gal +3% Outage):
- 78″ Diameter x 17’ seam to seam
- Pressure vessel hydrotested to 40 PSI
- Global hydraulic vibrator
- 4 stage double acting hydraulic hoist cylinder
- Full opening hydraulic lift rear door c/w locking style top hinge and 6 pin wheel door locks
- Recessed liquid level indicator on the D/S c/w indicator with grab handle
- 3″ x 30 PSI pressure relief vent
- Locking style top hinge to safely hold the rear door open
- Operating Temperature -20 degrees F to 200 degrees F
- 8″ Primary internal shutoff SS float ball and rubber seat assembly with 6″ flanged outlet
Product Valves
- 4” Betts load valve c/w 6″ sandpipe and aluminum camlock/cap D/S
- 4″ Betts load valve c/w aluminum camlock/cap P/S
- 6” Betts discharge valve c/w aluminum cap (Center) All rear valves heated, air and equipped with flip style valve controls
Blower & Associated Components
- Robuschi RB-DV 85 High Efficiency Tri-Lobe Design
- 27” Hg Maximum Vacuum (1600 CFM)
- Oil Free Operation (Except Sealed Reservoirs)
- 6″ Four-Way Divertor Valve (Vacuum to Pressure Modes)
- 6″ Double Door Check Valve (To Prevent Blower Back Spin)
- Pre-stage housing c/w 16″ Dia. x 5 Micron Rating (Washable) Blower Filter
- High Torque/High Temp Blower Drive Coupling with Flexible Insert
- One Exhaust Silencer, One Intake Silence
- High temperature blower alarm c/w gauge
- Diesel flush ball valve assembly
Equipment
Rig to Pull Pup (Standard)
- Doghouse
- Hydraulics required c/w hose and fittings to operate trailer functions
Toolbox
- One 60” W x 17” D x 17” H steel box c/w 2 access doors D/S (slope back)
- Two 22” W x 22” D x 40” H vertical cabinets c/w heater, lights, hooks D/S and P/S
- 2 rear skirt fitting boxes
Paint / Coating
- Entire tank and body of vacuum system will be sandblasted, primed and painted up to 2 colors
Frame, Decking, Trim
- Full length 1/8” checker plate hose tray/fender assembly with heavy duty outrigger supports & 1-1/4” steel tubing handrails, close in plates
- Ladder P/S
- Code rear bumper (flip up style)
- Slide out style chain hangers
- 4 flip style placards
- Mud flaps c/w anti-sail brackets
- 20 lb. fire extinguisher with mounting bracket and cover
- 50’ ground cable c/w reel